2023 Author: Philip Bishop | [email protected]. Last modified: 2023-05-24 22:24
- Purpose
- Collector concept
- Device
- Installation process
- Collector components
- Check
Everyone strives to create excellent living conditions in their home. Special attention is paid to warmth and comfort. For this purpose, a warm floor is created, which can be presented in various versions. But it should be noted that it is very important to carry out all the preparatory measures before this procedure. It all starts with the walls, since a collector for a warm floor is installed here. The place must be prepared with high quality and in accordance with the requirements. It is presented in the form of a cabinet, which is attached to the wall in a prepared niche. Fixing the exercise at the base of the floor.
Purpose
No difficulties should arise to arrange a warm floor mixing on your own. Only minimal knowledge and understanding of technology is needed. The installed cabinet is designed to hide the manifold.

But in addition, it hides all the heating pipes with all the other components of supplying the house with heat. Devices to regulate the underfloor heating system can also be installed. The collector cabinet has its own dimensions, which are equal to 60 * 40 * 12 cm. It takes up little space, and plays an essential role.
After the installation of the cabinet for the underfloor heating collector is completed, the supply and return pipes are placed in it. Each of them has its own purpose. The return one serves to collect the water that has given up its heat to the system, return it to heating, where it increases the temperature. The supply plays the opposite role - the supply of hot water from the boiler throughout the entire system. It also has another main function - the supply of coolant.

In the manifold cabinet, the ends of the above pipes must be closed with shut-off valves. This allows you to remove any specific room in the house or apartment from the heating system. It just closes both valves for the warm floor. Such actions are usually carried out in order to save energy, as well as when carrying out repair work in one of the rooms.
The plastic pipe must be securely fixed to the metal valve. This is where the compression element (fitting) comes to the rescue. All these components should be stocked up before starting the installation of the entire system, so as not to be distracted anywhere in the future.
There must be consistency in the operation of the underfloor heating system. The circulation pump is responsible for this.
Collector concept
When all the components of the system are available, you can begin to study the reservoir as the main component. In simple terms, this is a pipe segment that has several outlets located on one side. The valve is connected.

For this, special fittings are used through which the contours of metal-plastic pass.
The distribution manifold is presented in the form of a pipe segment with branches. Its opposite end will have an outlet that is muffled with a conventional plug. It will not be superfluous to place a splitter there at all.
As for the splitter, on one side of it you can install a drain valve, and on the other - an automatic air vent. The last component of the collector floor heating system helps to remove unintentional air build-up.
The described arrangement of all elements of the collector system refers to the return and supply pipelines. When buying a comb for underfloor heating, you should purchase it in pairs. There are other subtleties of working with the collector. Some of them may prompt the store when choosing individual system components. Much will depend on what kind of floor heating power is chosen for indoor installation.
Device
When the installation of a water-heated floor is carried out, the work may take a little time. Everything will depend on the length of the warm floor, the availability of appropriate equipment and materials, as well as skills.
A collector with a pump for underfloor heating refers to one of the components of the entire system to provide heat to the room. At the same time, it has a peculiar character of performance with its own nuances. The most basic of them is that the preparation of pipelines is carried out separately from the entire system. And this is despite the fact that the coolant circulates through all pipes at the same time.

A manifold is necessary in order to be able to isolate the supply and return pipes from the water heating system. The kit contains the following components without fail:
- Pumping group.
- Heating medium distributor.
- Cooled back water collector.
Nobody thinks about how much it costs to install a warm floor. It is best to purchase components in aggregate and from one manufacturer. This is the only way to get the highest quality. In addition, in this case, the cost will be less, regardless of the length of the underfloor heating circuit.
Installation process
Collector underfloor heating can be installed independently or with the help of specialists. True, in the latter case, you will have to pay in full for the services, which will increase depending on which mixing unit for the heated floor will be installed, as well as how many meters of the heated floor will have to be laid on the base of the floor. In this case, you should think about the quality of the surface, which should be carefully prepared.
It doesn't matter if the work is done independently or by specialists. In one case or another, you yourself should pay attention to the process itself, remembering the intricacies of installation. This will give you the best possible result. Initial work will depend on the location of the main pipeline of the boiler device, as well as the pipeline of individual rooms in an apartment or house. It is from this site that the whole process will start. The reference point for the contour of the warm floor is usually taken in the wall. In this case, a section is selected that is at the same distance to the long points of the pipes from the terminal branches. This solution will solve the issue with the hydraulic mode of operation. The entire underfloor heating system must have optimal components.

It is possible to encounter a large number of rooms to be heated by the system. In this case, you need to think about how much the warm floor consumes. The best option is to arrange not one, but several nodes at once, allowing you to separate the coolant. This solution will bring the best heat dissipation, the fastest warm-up, cost savings.
Collector components
The device of the underfloor heating system using a collector includes the following main components, which cannot be dispensed with:
- Collector supply to the floor. It can also be called a flow control valve for a single branch.
- Mixing unit as well as a three-way valve.
- Servo-assisted regulation valve. This is the so-called return collector, which is almost identical in cost to the supply.
- A circulation pump with a drainage device.
- System automation group.
-
Combs, but if necessary. They are more suitable for supplying heat to a room using radiators.
Underfloor heating collector
Automatic control valves allow you to interrupt the supply of heat carrier to the warm floor after reaching a certain temperature. It no longer enters the circuit until it cools down. Here it does not matter how much the warm floor consumes, since all indicators will decrease due to constant monitoring. They also use flow meters that allow setting the required parameters of the heat supplied to the room. Setting up is very easy and straightforward. They are located on the back of the comb.
Both combs are connected to each other using a circulation pump. It allows water to constantly circulate through the underfloor heating system. It should be noted that each of the elements of the collector group is purchased both separately and in aggregate. In the latter case, you should not worry that something will not be enough and will not be available. But collecting the entire system on your own requires some knowledge. So, for example, it is worth knowing that you will have to purchase a drainage drain valve for the pumping group. In addition, it will be necessary to install the collector cabinet itself before starting all work, which is additionally equipped with a point for venting air from the system.

The comb system is equipped with various measuring and indicating instruments. This includes pressure gauges, thermometers, heating sensors, and more. The latter, by the way, are installed in the floor screed. What kind of floor filling option to choose should be guided by the requirements of the underfloor heating system itself, its features.
The quality of the device of the collector group for a warm floor will subsequently affect the performance of the heating system. In addition, the reliability of a water-heated floor is based on all its components. Close attention during installation will allow you to get the desired result that can last for a long time.

Check
When the entire system is installed, and the components are connected to each other, are located in the right places, you should first perform a test run of the system. After warming up, you can find out the defects and defects in work. In this case, the pressure in the system should be greater than the operating pressure by about a quarter. All joints must be tight and not leak.
When everything is refined, you can start with the normal circulation of the warm floor.

Video:

Video:

Video:

Video: