It is often difficult to find a place for a ventilation system in an apartment. Enervent offers compact Piccolo and Liggolo models for installation in the kitchen above the stove. These settings are extremely functional. The cooker hood removes odors during the cooking process, and normally serves as a cooker hood. A rotary recuperator built into the unit recovers heat from the extract air, thereby increasing the supply air temperature. The design is arranged in such a way that the exhaust "kitchen" air is immediately discharged to the street, therefore it is possible to avoid its spreading through the apartment. Additionally, the system has an 800W air heater that provides heat to the supply air if it is cold outside. Fresh and warm air is evenly distributed to all rooms through air ducts, ensuring comfort.

Comfortable microclimate at home
Today people spend most of their lives in confined spaces, which is why it is so important to take care of the cleanliness and freshness of indoor air. With our energy efficient units, the used air will be removed from the room and replaced with fresh outside air, which has been previously cleaned, heated or cooled, and the restoration of humidity in winter will avoid excessive dryness of the air.
A ventilation unit is best suited if you are looking for a solution to a medium-sized apartment or house. The advantages of the system are obvious:
- the device has low power consumption and high efficiency of heat recovery, pressure loss through the device is minimized;
- the structure of the device is such that it does not freeze at temperatures below zero;
- advantage is high quality bag filters that provide fresh and healthy indoor air;
- the ventilation unit is also well suited for public spaces that require less air.
Energy efficient ventilation
The ventilation units use highly efficient rotary heat exchangers, which allow using the heat of the extract air to heat the supply air, while the cooled air is discharged outside. This allows you to significantly reduce heat losses through the air ventilation system, which can be up to 35% of all heat losses. Rotary heat exchangers have an annual efficiency of about 70%
Piccolo OFF
It is not easy to find a place for a ventilation unit in an apartment. Therefore, there is the popular compact Piccolo model developed, for example, above the stove in the kitchen. The system is practically silent. Fittings for kitchen furniture are included as standard, making the installation process quick and easy. Ventilation system Piccolo ON is available for both right and left hand. These models necessarily use a kitchen hood and are installed above the hob.

Piccolo ON
Not all kitchens can find space for a ventilation unit, which is why the company developed the Piccolo OFF. This system, like the Piccolo ON, is always connected to a cooker hood, but unlike it, it is not a direct connection, but a duct connection. In this case, the Piccolo OFF control is located on the front panel of the hood, and the extract air enters the ventilation unit. Ventilation systems Piccolo OFF are manufactured with access both from the right and from the left.

Liggolo
The Piccolo product line includes the Liggolo horizontal ventilation unit, which is specially designed for ceiling mounting. This allows you to install a ventilation system even if there is no free space on the walls. The connection of the kitchen hood to the unit is duct.
The Piccolo and Liggolo systems are controlled by changing the air flow rate with a regulator located on the hood panel. The fan has three speed settings. In addition to the fan speed regulator, there is a damper regulator on the panel. The damper must be manually opened when cooking, turning on the hood (A) and selecting the fan speed (B). The damper closes automatically after 60 minutes.
The control device will take care of the rest. The outdoor thermostat controls the heat exchanger by activating or deactivating it depending on the air temperature. The operation of the electric re-heater is controlled by the supply air thermostat, and the defrost function of the recuperator is controlled by the extract air thermostat, which switches off the supply air fan if the extract air temperature falls below the set value

The CTRL control system expands the control area of Piccolo and Liggolo units with the ECC-05E operating panel. The hood of the cooker hood opens manually when switched on during cooking and closes automatically after 30 or 60 minutes. It can also be closed manually before the expiration of this period. Humidity control (RH) and the presence / absence control (home / away (KOPO)) of fans are available as an option of the CTRL control system.
Specifications Piccolo
Air consumption Piccolo eco +74 / -74 l / s |
Volume Piccolo eco 0 - 409 m³ |
Fans Piccolo eco 119/119 W |
Power type 230 V / 50 Hz, 1 phase Circuit breaker 10 A |
Overheating protection is
Filter type F7 / F5 |
Air duct diameter Ø 125 mm Weight 46 kg |